SS-CPH90-150 www.goodmanmfg.com 6/11
Supersedes 3/11
Standard Features
• R-410Achlorine-freerefrigerant
• High-eciencyscrollcompressor
• Coppertube/aluminumncoils
• Contactorwithlugs
• High-capacity,steel-casedlterdryer
• Single-pointentry
• 24-voltterminalstrip
• Convertible
• Easytoservice
• Built-inlterrackwithstandard2”lters
• Bottomutilityentry
• AHRICertied;ETLListed
Cabinet Features
• Heavy-gauge,galvanized-steelcabinetwith
UV-resistantpowder-paintnish
• FullPerimeterRail
• CurbFit
CPH CommerCial
up to 11.5 EER
up to 3.5 Cop
7½- to 12½-ton Self-Contained
PaCkaged Heat PumP
Cooling / Heating CaPaCitieS:
90,000 — 118,000 Btu/H
Contents
Nomenclature.............................................................................................2
ProductSpecications........................................................................... 3
ExpandedHeatingData...................................................................... 7
ExpandedCoolingData........................................................................8
AirowData............................................................................................... 16
HeatKitElectricalData...................................................................... 20
Dimensions................................................................................................ 24
WiringDiagrams.................................................................................... 28
Accessories............................................................................................... 34
*Completewarrantydetailsavailablefromyourlocaldealeroratwww.goodmanmfg.com.
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - CPH CommerCial

SS-CPH90-150 www.goodmanmfg.com 6/11Supersedes 3/11Standard Features• R-410Achlorine-freerefrigerant• High-eciencyscrollcompressor• Copper

Page 2

ProduCt SPeCifiCationSProduCt SPeCifiCationS10 www.goodmanmfg.com SS-CPH90-150exPanded Cooling data — 8½ tonSOutdoor Ambient Temperature65 75 85 95 10

Page 3

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 11exPanded Cooling data — 8½ tonS (Cont.)Outdoor Ambient Temperature65

Page 4

ProduCt SPeCifiCationSProduCt SPeCifiCationS12 www.goodmanmfg.com SS-CPH90-150exPanded Cooling data — 10 tonSOutdoor Ambient Temperature65 75 85 95 10

Page 5

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 13exPanded Cooling data — 10 tonS (Cont.)Outdoor Ambient Temperature65

Page 6

ProduCt SPeCifiCationSProduCt SPeCifiCationS14 www.goodmanmfg.com SS-CPH90-150exPanded Cooling data — 12½ tonSOutdoor Ambient Temperature65 75 85 95 1

Page 7

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 15exPanded Cooling data — 12½ tonS (Cont.)Outdoor Ambient Temperature65

Page 8

ProduCt SPeCifiCationSProduCt SPeCifiCationS16 www.goodmanmfg.com SS-CPH90-150airflow data — 7½ tonSStandard Belt Drive — Down ShotESP, In H2OTurns Op

Page 9

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 17airflow data — 8½ tonSStandard Belt Drive — Down ShotESP, In H2OTurns

Page 10 - ProduCt SPeCifiCationS

ProduCt SPeCifiCationSProduCt SPeCifiCationS18 www.goodmanmfg.com SS-CPH90-150airflow data — 10 tonSStandard Belt Drive — Down shotESP, In H2OTurns Op

Page 11

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 19airflow data — 12½ tonS Standard Belt Drive --- Down Shot ESP (in W.

Page 12

ProduCt SPeCifiCationSProduCt SPeCifiCationS2 www.goodmanmfg.com SS-CPH90-150nomenClature C P H 090 045 3 B X X X         Bran

Page 13

ProduCt SPeCifiCationSProduCt SPeCifiCationS20 www.goodmanmfg.com SS-CPH90-150Heat kit eleCtriCal data — 7½ tonSminimum airflow for eleCtriC HeatHeate

Page 14

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 21Heat kit eleCtriCal data — 8½ tonSModel and Heat Kit UsageMCA¹ at 2

Page 15

ProduCt SPeCifiCationSProduCt SPeCifiCationS22 www.goodmanmfg.com SS-CPH90-150Heat kit eleCtriCal data — 10 tonSkw CorreCtion faCtorkW Correction Fact

Page 16

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 23Heat kit eleCtriCal data — 12½ tonSkW Correction Factor for 1- &

Page 17

Product SPecificationSProduct SPecificationS24 www.goodmanmfg.com SS-CPH90-150dimenSionS20APPENDIX C UNIT DIMENSIONSHorizontal DischargeVertical Disch

Page 18

Product SPecificationSProduct SPecificationSSS-CPH90-150 www.goodmanmfg.com 2548”36” Min.48”48”75”unit clearanceSelectrical entrance locationS11⅝”1

Page 19

Product SPecificationSProduct SPecificationS26 www.goodmanmfg.com SS-CPH90-150roof curb inStallation — riggingProvisions for forks have been included

Page 20

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 27roof CurB inStallation (Cont.)Curb installations must comply with

Page 21

ProduCt SPeCifiCationSProduCt SPeCifiCationS28 www.goodmanmfg.com SS-CPH90-150wiring diagram — CPH090-120***3B/ 4B (for modelS witH Serial numBerS 09

Page 22

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 29wiring diagram — CPH090-120***3B/ 4B (Cont.) (for modelS witH Serial

Page 23

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 3ProduCt SPeCifiCationS — 7½ tonSCPH090 ***3B***CPH090 ***4B***CPH090 *

Page 24 - Product SPecificationS

ProduCt SPeCifiCationSProduCt SPeCifiCationS30 www.goodmanmfg.com SS-CPH90-150wiring diagram — CPH090-120***3B/ 4B/ 7B***TB1ORBRREPLACE JUMPER WITHSMO

Page 25

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 31wiring diagram — CPH090-120***3B/ 4B/ 7B*** (Cont.)REBTDRBCRHVDRYRVC1

Page 26

ProduCt SPeCifiCationSProduCt SPeCifiCationS32 www.goodmanmfg.com SS-CPH90-150TB1ORBRREPLACE JUMPER WITHSMOKE/FIRE DETECTORRDC3BL1PK240460BLORRDGRBKOR

Page 27

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 33wiring diagram — CPH150***3B/ 4B/ 7B*** (Cont.)REBTDRBCRHVDRYRVC1SEE

Page 28 - ⚠ Warning

ProduCt SPeCifiCationSProduCt SPeCifiCationS34 www.goodmanmfg.com SS-CPH90-150aCCeSSorieSItem # DescriptionFits Model Sizes14CURB90150 Roof Curb 14&q

Page 29

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 35noteS

Page 30

Product SPecificationSProduct SPecificationS36 www.goodmanmfg.com SS-CPH90-150Goodman Manufacturing Company, L.P., reserves the right to discontinue,

Page 31

ProduCt SPeCifiCationSProduCt SPeCifiCationS4 www.goodmanmfg.com SS-CPH90-150ProduCt SPeCifiCationS — 8½ tonSCPH102 ***3B***CPH102 ***4B***CPH102 ***7

Page 32

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 5ProduCt SPeCifiCationS — 10 tonSCPH120***3B***CPH120***4B***CPH120***7

Page 33

ProduCt SPeCifiCationSProduCt SPeCifiCationS6 www.goodmanmfg.com SS-CPH90-150ProduCt SPeCifiCationS — 12½ tonSCPH150XXX3BXXXCPH150XXX4BXXXCPH150XXX7BX

Page 34

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 7exPanded Heating dataCPH090 Outdoor Ambient Temperature65 60 55 50 47

Page 35

ProduCt SPeCifiCationSProduCt SPeCifiCationS8 www.goodmanmfg.com SS-CPH90-150exPanded Cooling data — 7½ tonSOutdoor Ambient Temperature65 75 85 95 105

Page 36

ProduCt SPeCifiCationSProduCt SPeCifiCationSSS-CPH90-150 www.goodmanmfg.com 9exPanded Cooling data — 7½ tonS (Cont.)Outdoor Ambient Temperature65 7